HW group · Monitor · brought to Israel by Antech

Sensors and detectors by HW group

Over 70 sensors and detectors for temperature, humidity, water leaks, energy, air quality, smoke, gas and vibration. Every one of them plugs into an HW group device, which reads it and raises the alert.

  • 6sensor families, from a rack thermometer to a three-phase MID meter
  • 1-Wire · 1W-UNIplug-and-play RJ11 sensors, chained from port to port
  • RS-485 · M-BusModbus/RTU and M-Bus meters on the device bus
  • IP67outdoor and frost-rated probes in the range
Scroll to explore

The range · 40 products

Meet the products, with your guide

Scroll through the range. Your guide introduces every family and explains each product as it comes into view.

01 · Temperature and humidity

Temperature and humidity

Digital 1-Wire, 1-Wire UNI, Pt100 and RS-485 probes for racks, rooms, fridges, freezers and outdoor spots.

Let me show you the temperature and humidity probes. Most of them plug into an RJ11 port and take their 5 V from it, so there is no extra power supply to think about.

1WR-Temp Rack19 2p

1WR-Temp Rack19 2p

01

1-Wire temperature sensor for 19 inch racks, two RJ11 ports for daisy-chaining

  • Measuring range-10 to +80 °C
  • Accuracy±0.8 °C in whole range, resolution 0.10
  • Interface1-Wire, 2x RJ11, 5 V, 3m cable
  • ProtectionIP30, 44 × 84 × 19 mm

I sit in a 19 inch rack and measure -10 to +80 °C. My two RJ11 ports let you chain the next sensor from me.

Temperature measuring in IT cabinets (racks) and server roomsAsk about this
1WR-Temp IP67

1WR-Temp IP67

02

Stainless steel 1-Wire temperature probe with IP67 protection, in 1 m, 3 m or 10 m lengths

  • Measuring range-10 to +80 °C
  • Accuracy±0.8 °C, resolution 0.10
  • Cable length1 m / 3 m / 10 m
  • Interface and protection1-Wire (RJ11, 5 V), IP67

I am the general purpose probe: stainless steel, IP67, immersible to 1 m. You pick a 1 m, 3 m or 10 m cable.

IT and industry, outdoor and indoor useAsk about this
1WR-Temp Flat 3m

1WR-Temp Flat 3m

03

Stainless steel temperature probe with a flat cable that routes under a fridge door seal

  • Measuring range-30 to +60 °C
  • Accuracy±0.8 °C from -10 to +60 °C, ±2.0 °C in whole range
  • Cable length3m, flat connection cable
  • Interface1-Wire (RJ11, 5 V / 1 mA)

My flat cable slips under a refrigerator or freezer door seal. The stainless steel probe measures -30 to +60 °C.

Temperature monitoring in IT cabinets, fridges, freezers, high humidity environments and outdoorAsk about this
1WR-Temp Outdoor 3m

1WR-Temp Outdoor 3m

04

Outdoor 1-Wire temperature probe, stainless steel IP67 casing, -50 to +125 °C

  • Measuring range-50 to +125 °C
  • Accuracy±0.8 °C from -10 to +80 °C, ±2.0 °C from -30 to +125 °C
  • Cable length3m PVC cable
  • Interface and protection1-Wire (RJ11, 5 V / 1 mA), IP67

I go outside. My stainless steel casing is IP67 and I read from -50 to +125 °C, so frost and heat are both fine.

Outdoor temperature monitoring, pharmaceutical and food industryAsk about this
1WR-Humid

1WR-Humid

05

Humidity-only 1-Wire probe for IT racks, 0 to 100 % RH, 1 m or 3 m cable

  • Measuring range0 to 100 % RH
  • Accuracy5 % RH (0 to 100 % RH non-condensing, 25 °C), linearity ±2.0 % RH
  • Cable length1m / 3m
  • Interface and protection1-Wire (RJ11, 5 V), IP65

I only measure relative humidity, 0 to 100 % RH. Clip me to a cable bundle in a rack and I report over 1-Wire.

Monitoring of humidity in IT rooms and various other environmentsAsk about this
1WR-HTemp 3m

1WR-HTemp 3m

06

Combined 1-Wire temperature and humidity rod sensor for indoor and outdoor use

  • Temperature-30 to +80 °C, ±0.8 °C from 0 to +60 °C
  • Humidity0 to 100 % RH, 5 % RH (non-condensing, 25 °C)
  • Cable length3m
  • Interface and protection1-Wire (RJ11, 5 V), IP40

I give you two values from one RJ11 port, temperature and relative humidity. I am a slim rod, 78 × 10 × 6 mm.

IT cabinets and racks, monitoring of temperature and humidity in industrial areasAsk about this
1WR-HTemp Rack19 2p

1WR-HTemp Rack19 2p

07

1U rack temperature and humidity probe with two RJ11 ports for daisy-chaining

  • Temperature-10 to +80 °C, ±0.8 °C
  • Humidity0 to 100 % RH, 5 % RH (2 to 80 % RH non-condensing, 25 °C)
  • Interface1-Wire, 2x RJ11 daisy-chainable, 3m cable included
  • ProtectionIP23, 44 × 84 × 19 mm

I am the rack version with both values. Mount me as a 1U device at the front or back and chain the next sensor through my second port.

IT cabinets (racks) and server roomsAsk about this
1WR-HTemp Outdoor 3m

1WR-HTemp Outdoor 3m

08

Outdoor temperature and humidity probe on the 1-Wire bus, IP64, 3 m cable

  • Temperature-30 to +85 °C, ±0.8 °C
  • Humidity0 to 100 % RH, 5 % RH (2 to 80 % RH non-condensing, 25 °C)
  • Cable length3m
  • Interface and protection1-Wire (RJ11, 5 V / 1 mA), IP64

I measure temperature and humidity outdoors. IP64 probe, 15 mm across and 112 mm long, on a 3 m cable.

Outdoor monitoring of temperature and humidityAsk about this
HTemp-1Wire-Box2

HTemp-1Wire-Box2

09

Wall mount temperature and humidity sensor box with two RJ11 ports

  • Temperature-10 to +80 °C, ±0.8 °C
  • Humidity0 to 100 % RH, 5 % RH (2 to 80 % RH non-condensing, 25 °C)
  • Interface1-Wire, 2x RJ11, 5 V / 1 mA, 3m cable included
  • ProtectionIP30, 79 × 71 × 30 mm

I am the wall box for offices and storage rooms. Two RJ11 ports let you daisy-chain, and a 3 m cable comes with me.

Monitoring of temperature and humidity in IT rooms, offices and storage housesAsk about this
1WU HTemp B1

1WU HTemp B1

10

Small 40 × 40 mm indoor temperature and humidity box with RJ11 (1WU) interface

  • Temperature-40 to 85 °C, ±0.5 °C, resolution 0.1 °C
  • Humidity0 to 100 % RH, 5 % RH / 25 °C
  • InterfaceRJ11 (1WU), bus up to 60 m, 3-meter RJ11 cable included
  • ProtectionIP30, 40 × 40 × 20 mm

I am the small 4 by 4 cm box. Stick me to a wall, ceiling or desk with tape and I report temperature to ±0.5 °C plus humidity.

Households, commercial buildings and school buildingsAsk about this
Temp-1Wire Pt100

Temp-1Wire Pt100

11

Industrial Pt100 temperature probe, -50 to +200 °C, IP67, 8-point calibration

  • Measuring range-50 °C to +200 °C
  • Accuracy±(0,25 + 0,002|t|), resolution 0.10 °C, calibration in 8 points
  • Cable length3m
  • Interface and protectionRJ11 (1Wire or 1Wire UNI), IP67

When you need industrial precision, I am the Pt100 probe. -50 to +200 °C, IP67, and I can be calibrated at 8 points.

Storages, food processing, freezers, medical and laboratory environments, agricultureAsk about this
1WU-Temp Pt100 Frost 3m

1WU-Temp Pt100 Frost 3m

12

Cryo Pt100 temperature probe, -200 to +160 °C, IP67, 8-point calibration

  • Measuring range-200 °C to +160 °C
  • Accuracy±(0,25 + 0,002|t|), resolution 0.10 °C, calibration in 8 points
  • Cable length3m
  • Interface and protectionRJ11 (1Wire or 1Wire UNI), IP67

I am the cryo version. -200 to +160 °C with the same Pt100 precision and IP67 protection.

Cryo applications, freezers, food storages, medical and laboratory environmentsAsk about this
Temp-1W-UNI Pt100 Cable

Temp-1W-UNI Pt100 Cable

13

Pt100 probe on a 2 m silicon cable with a 1-Wire UNI converter, second probe input free

  • Measuring range-50 to +200 °C (probe only)
  • Accuracy±0.3 °C in whole range, resolution 0.10, 8 calibrated points
  • Cable length2m silicon cable, probe IP67
  • Interface1-Wire UNI (RJ11, 5 V / 20 mA)

I combine a Pt100/A probe with the 2xPt100 converter on the cable, ±0.3 °C in the whole range. You can add a second Pt100 or Pt1000 probe to me.

Fridges, freezers, pharmaceutical and food industryAsk about this
Converter 2xPt100 1W-UNI

Converter 2xPt100 1W-UNI

14

Connects one or two Pt100 or Pt1000 probes to the 1-Wire UNI bus, 2, 3 or 4-wire

  • Measuring range-200 to +850 °C (Pt-100), 2-wire, 3-wire or 4-wire probes
  • Accuracy±0.3 °C up to +650 °C, ±0.6 °C up to +850 °C (at +25 °C converter temperature)
  • Interface1Wire-UNI, 2x RJ11 daisy-chain, max. 60m, bus powered
  • Calibration8 points, 65 x 80 x 30 mm

Bring your own Pt100 or Pt1000 probes and I put them on the 1-Wire UNI bus. I detect the probe type myself and cover -200 to +850 °C.

Industrial systems, cooling plants, HVAC in smart buildings, food and pharmaceutical storagesAsk about this
HWg HTemp-485 T3411 / T3419, HWg PHTemp-485 T7410

HWg HTemp-485 T3411 / T3419, HWg PHTemp-485 T7410

15

RS-485 temperature and humidity sensors with LCD display, T7410 also measures pressure

  • TemperatureT3411 and T7410: -30 to +80°C, T3419: -30 to +105°C, accuracy ±0.4°C
  • Humidity0 to 100%, ±2.5%RH (5 to 95% / 23°C)
  • InterfaceRS-485 (HWg-Poseidon protocol, 9600 8N1), up to 1000m, power 9..30V / 0.5W
  • ProtectionProbe IP40, box IP65 (IP54 for T7410)

I talk RS-485 to a Poseidon unit over up to 1000 m and show my values on a display. Several of me can share one line.

Outdoor usage with Poseidon units (T3411, T3419); indoor version with pressure (T7410)Ask about this

02 · Water leak detection

Water leak detection

Spot detectors and sensing cable units that catch the first drops of water under floors, around pipes and cooling units.

Water is the quiet enemy of a server room. Here are the spot detector and the sensing cable units that tell you about the first drops.

Flood detector 1W-UNI 3m

Flood detector 1W-UNI 3m

16

Spot water detector with four pins, 3 m cable straight into an RJ11 port, IP67

  • Output states0 = OK, 1 = flood
  • Cable length3m, 1x RJ11
  • Interface1-Wire UNI, bus powered, max. 60 m from the active port
  • ProtectionIP67, sensor can be submerged in water

I am a spot detector. Four pins on my body sense water at one point and I report 0 or 1 over the 1-Wire UNI bus.

Flood detection, lying on the floor or attached to the floor or a wallAsk about this

Sensor WLD Relay 1W-UNI

17

Connects one WLD sensing cable zone (up to 185 m) to a 1W-UNI port or any DI via relay

  • Max. zone length185 m, WLD sensing cable type A/B
  • Output states0 = OK, 1 = sensing cable flooded, 2 = sensing cable disconnected
  • Relay outputNO/NC, 50 V / 1000 mA, external 12V required
  • Interface1-Wire UNI (RJ-11, 5 V / 40 mA) or standalone with 9-15 V / 20 mA

Give me a WLD sensing cable and I watch up to 185 m of it. I report flooded or disconnected over 1W-UNI, or switch my relay for any digital input.

Under raised floors, leaky pipes, drip trays and under air-conditioningAsk about this
WLD-ECHO

WLD-ECHO

18

Standalone two-zone water leak detector with audible alarm and relay, 2x AA batteries

  • Zones2x WLD zone for sensing cable A/B, max. 185 m each
  • Relay output1x DO latching relay (25 V / 0.5 A)
  • Power supply5-30 V DC (12 V DC nominal), typ. 20 mA, or 2x AA batteries
  • Operating temperature-10 °C to 60 °C, 76 × 35 × 144 mm

I work on my own: two sensing cable zones up to 185 m each, a built-in audible alarm, LEDs and a relay for your alarm system. Two AA batteries or 5 to 30 V DC.

Data centers, server rooms, HVAC systems, boiler rooms, basements, hotels, hospitalsAsk about this

03 · Energy meters, current probes and power detectors

Energy meters, current probes and power detectors

Clamp-on and shunt current probes, mains voltage sensors and DIN rail electricity meters with M-Bus or Modbus.

This is where you watch power. The current probes clamp on without cutting a wire, and the DIN rail meters report consumption over M-Bus or Modbus.

30A AC Current probe 1W-UNI 2

30A AC Current probe 1W-UNI 2

19

Split-core clamp for single-phase AC current up to 30 A, no need to cut the wire

  • Measuring range0 to 30 A AC
  • Accuracy±2.0 A, resolution 0.10, 16-bit A/D converter
  • Cable length3m (1m lead between transformer and converter)
  • Interface1-Wire UNI (RJ11, 5 V / 10 mA), electrically isolated, measured voltage max. 400 V

Open my split core, slip it around one insulated wire, and I read AC current up to 30 A. My 1-Wire UNI side is isolated from the mains.

Power consumption of racks, BTS's or server roomsAsk about this
100A (30A) DC Current probe 1W-UNI

100A (30A) DC Current probe 1W-UNI

20

Shunt-based DC current probe, 0-100 A or 0-30 A versions, reports current direction

  • Current range0-100 A DC (100A version), 0-30 A DC (30A version)
  • Accuracy2%, resolution 0,1 A
  • Measured voltageMax. 60V, 1-Wire UNI bus electrically isolated from the measured circuit
  • Interface2x 1W-UNI for daisy-chaining, bus powered, 1m cable between shunt and converter

My shunt sits in the DC circuit and I report current with its sign, so you see charging and discharging. Choose the 100 A or the 30 A version.

Telco cabinets, BTS stations, battery charging, high-capacity UPS'sAsk about this
Sensor 230V AC 1W-UNI

Sensor 230V AC 1W-UNI

21

DIN rail sensor that measures the actual mains voltage, 100 to 240 V AC, on the 1-Wire bus

  • Measuring range100-240V AC
  • Accuracy5%, resolution 1V, measuring period approximately 1s
  • Interface1-Wire UNI, electrically isolated from the mains part
  • MountingDIN rail (2-modules wide), 88 x 64 x 37 mm

I measure the real mains voltage, 100 to 240 V AC, and report it over 1-Wire UNI. I sit on a DIN rail, two modules wide.

AC power network voltage measuring with Poseidon and HWg-Ares unitsAsk about this
Power Detector 110-230 V

Power Detector 110-230 V

22

Plug-in voltage presence detector with isolated relay output for any digital input

  • DetectsPresence of voltage between 110-230 V AC
  • Relay outputGalvanic insulated, up to 50 V / 130 mA
  • Closed status resistanceMax. 10 Ohm
  • VersionsINT, EU, UK and US wall plugs

Plug me into a socket and I close a contact while mains voltage is present. Wire that contact to any digital input.

Digital input (DI) of all HW group devicesAsk about this
PowerEgg2

PowerEgg2

23

Mains voltage detector and switch between two IEC-320 connectors, 110 to 230 V AC

  • Detects110 to 230V AC mains voltage, power failure indicated with a relay contact
  • Control inputControl voltage 3 to 12V, or low-voltage closing contact
  • ConnectorsIEC-320 plug (C14) at the input, socket (C13) at the output
  • IsolationControlling and controlled circuits electrically isolated

I sit between a C14 plug and a C13 socket. I report whether mains is present, and I can cut the output when you tell me to, for a remote server restart.

Remote server restart, switching cooling, voltage monitoring at UPS input/outputAsk about this
PRO1 Series MID (PRO1-Mb / PRO1-Mod)

PRO1 Series MID (PRO1-Mb / PRO1-Mod)

24

Single phase DIN rail energy meter, 5(45) A, M-Bus (PRO1-Mb) or Modbus RTU (PRO1-Mod)

  • Rating230V AC, Ib 5A, Imax 45A, 50Hz
  • Accuracy classB (=1% accuracy), EN50470-1/3, MID
  • InterfaceM-bus (PRO1-Mb) or RS485 MODBUS RTU (PRO1-Mod), range 1000m
  • Size17,5 mm wide, 35mm DIN rail, IP51

I am the compact single phase meter, one DIN module wide, 5(45) A, accuracy class B. I report over M-Bus or Modbus RTU depending on the version.

Single phase energy metering, indoor on a 35mm DIN railAsk about this
PRO2 Series MID (PRO2-Mb / PRO2-Mod)

PRO2 Series MID (PRO2-Mb / PRO2-Mod)

25

Single phase DIN rail energy meter, 5(100) A, M-Bus (PRO2-Mb) or Modbus RTU (PRO2-Mod)

  • Rating230V AC, Ib 5A, Imax 100A, 50Hz
  • Accuracy classB (=1% accuracy), EN50470-1/3, MID
  • InterfaceM-bus (PRO2-Mb) or RS485 MODBUS RTU (PRO2-Mod), range 1000m
  • Size35,8 mm wide, 35mm DIN rail, IP51

I am the bigger single phase meter, up to 100 A direct. I have forward and reverse S0 pulse outputs plus M-Bus or Modbus RTU.

Single phase energy metering up to 100 A, indoor on a 35mm DIN railAsk about this

PRO380 Series MID (PRO380-Mb / PRO380-Mod)

26

Three phase DIN rail energy meter, 5(100) A direct or 1,5(6) A CT, M-Bus or Modbus RTU

  • Rating3*230/400V AC, Ib 5A / Imax 100A (direct), Ib 1,5A / Imax 6A (CT version)
  • Accuracy classB (=1% accuracy), EN50470-1/3, MID
  • InterfaceM-bus (PRO380-Mb) or RS485 MODBUS RTU (PRO380-Mod), range 1000m
  • Size70 mm wide, 35mm DIN rail, IP51

I meter three phases: direct connection up to 100 A, or the CT version through current transformers with a settable ratio. M-Bus or Modbus RTU.

Three phase energy metering, 3P 4W or 3P 3W Delta, direct or via current transformersAsk about this

ED 310 / ED 310.I

27

Poly-phase 4-tariff electricity meter, direct to 63 A or via CT, RS 485 or M-Bus module

  • Rating3 x 230 / 400 V, 15 mA to 63 A direct (ED 310) or 5 mA to 7.5 A via CT (ED 310.I)
  • Accuracy classA or B as per EN 50470-1, 50470-3
  • InterfaceS0 pulse output, opto-interface, optional RS 485 (up to 1200m) or M-Bus module
  • ProtectionIP 20, DIN bar installation, -25°C to +55°C

I count consumption and supply in up to four tariffs, directly up to 63 A or through current transformers. Add an RS 485 or M-Bus module and I join the bus.

Monitoring consumption and supply of active electricity in the retail consumption areaAsk about this

M-Count 2C

28

Two-channel pulse logger that puts S0 meter pulses on M-Bus, battery backed, 1 DIN module

  • InputsTwo completely separate pulse input channels (reed contact, S0 optional)
  • InterfaceM-Bus according to EN1434-3 standard, 2400 baud
  • PowerFrom the M-Bus, internal lithium battery backup approx. 200 days
  • Size1-module (18 mm), 82x63x17.5 mm, DIN-rail 35 mm, -20° up to +65°C

I collect pulses from two meters, gas, water or electricity, and hand the counts to M-Bus. A lithium battery keeps me going if the bus fails.

Collecting impulses from gas-, water-, electricity- or other meters with S0 pulse outputAsk about this

04 · Smoke, gas, motion and vibration detectors

Smoke, gas, motion and vibration detectors

Third-party detectors with relay or contact outputs: smoke, combustible gas, PIR motion and vibration.

Each of these ends in a contact, so a digital input can carry the alarm for smoke, gas, movement or a shock to a window.

FDR-26-S smoke detector

29

4-wire 12 V smoke detector with Form A auto-reset relay, up to 30 units per loop

  • Wiring4-wire, 12V DC
  • CurrentStandby 320 μA, alarm 35mA max., start-up time 60 seconds
  • Alarm contactForm A/Auto Reset, relay rating 1A@30VDC, 0.5A@125VAC
  • BaseP/N774912, maximum 30 smoke detectors in the same loop

I am the 4-wire smoke detector head on a twist-lock base: 12 V DC, a Form A relay contact, and up to 30 of me on one loop.

Ceiling or wall mounting in accordance with the fire standard in your countryAsk about this

Gas leak detector GS-133

30

Combustible gas detector (methane, propane, butane, hydrogen), two alarm levels, relay

  • SensitivityMethane level 1 10±3 % LEL, level 2 18±3 % LEL; hot platinum filament
  • Relay outputDry contact C/NO/NC, optional for 1st or 2nd level, max. 230 V AC / 5 A
  • Power supply12 V DC ± 20 %, 100 mA (150 mA when relay is activated)
  • EnvironmentIndoor use, -10 to +40°C, IP30, response time 20 s

I sniff for natural gas, propane, butane and hydrogen at two concentration levels. I beep at 94 dB and close a relay you can use for a gas valve or an alarm input.

Flats, domestic premises, commercial areas or gas boiler houses (non-explosive areas)Ask about this

PIR detector JS-20

31

Wired PIR motion detector for a secured area, component of an intrusion alarm system

  • Type designationJS-20
  • Intended useMovement detection in a secured area, component of an intrusion alarm system
  • ConnectionConnected to the control panel by a cable
  • StandardsEN 55022:2010, EN 50130-4:2011 (EMC), EN 50581:2012 (RoHS)

I am a wired PIR detector. I sense people moving in a secured area and signal it over my cable to the control panel.

Movement detection in a secured areaAsk about this
SS14 vibration sensor

SS14 vibration sensor

32

Shock and vibration detector for windows, doors and fixtures, with sensitivity trimmer

  • Impact distanceGlass 1 to 6 m, wood 2 to 4 m, wall 0 to 1 m
  • Alarm contactNC, 100mA@30V max, 2 seconds; tamper contact 0.2 A - 24 Vcc
  • Supply13.8Vdc (9V min 15V max), 9mA standby, 21mA max
  • Temperature-20°C to +50°C, ABS housing, L77 H36 P20 mm

Fix me to a window or door frame. A hard knock closes my alarm contact for 2 seconds, and a trimmer sets how sensitive I am.

Protect fixtures, windows, box, or any passage where break-in attempts must be detectedAsk about this

05 · Air quality (CO2, VOC)

Air quality (CO2, VOC)

Indoor sensors that add CO2 or VOC readings to temperature and humidity, for offices, schools and public rooms.

Here I check the air you breathe. These boxes report CO2 or VOC together with temperature and humidity, so a stuffy room shows up before anyone complains.

Sensor CO2 1W-UNI

Sensor CO2 1W-UNI

33

Combined temperature, humidity and CO2 sensor in one box, RJ11 1-Wire UNI interface

  • CO2300 to 40 000 ppm, accuracy 50 ppm +3 %, resolution 1 ppm (0 to 2000 ppm)
  • Temperature and humidity0 to 50 °C (0.8 °C), 0 to 95 % RH (5 % RH)
  • Interface1-Wire UNI (RJ11), 5V from the port, max. 30 m, max. 1 sensor per active port
  • ProtectionIP30, 60 × 60 × 20 mm

I report three values on one RJ11 port: temperature, humidity and CO2 from 300 to 40 000 ppm. Give me 7 days to calibrate in the room.

Home, office, or public installation; wall, ceiling or deskAsk about this
1WU-HTPVoC B1

1WU-HTPVoC B1

34

Four quantities in a 4 × 4 cm box: temperature, humidity, air pressure and VOC air quality

  • Air quality (VOC)0 to 60 000 ppb, accuracy 15 %, resolution 1 ppb
  • Atmospheric pressure30 to 110 kPa, accuracy 12 Pa (95 to 105 kPa / 25 °C)
  • Temperature and humidity-30 to +70 °C, 0 to 100 % RH (5 % RH / 25 °C)
  • InterfaceRJ11 (1WU), max. 30 m, 1 sensor per port, IP30, 40 × 40 × 20 mm

I am four sensors in one small box: temperature, humidity, atmospheric pressure and VOC air quality in ppb. The bus sees me as four independent sensors.

Home, office, or public installation; wall, ceiling or deskAsk about this

HTemp CO2 485-RTU (RK-CHM series)

35

Wall CO2, temperature and humidity sensor on RS485 Modbus RTU, LED or touch display

  • CO2400 to 10 000ppm, accuracy ±30ppm ±3% of the range (0 to 2000ppm)
  • Temperature and humidity± 0,5°C (20 to 40°C), ± 3 % RH (20 to 80 %RH)
  • InterfaceRS485, protocol ModBus RTU, 1200 to 57600 Bd, max. 254 sensors on the line
  • Power and protection12 to 30 VDC, IP30, 103 x 100 x 25 mm

I measure CO2, temperature and humidity on the wall and answer Modbus RTU over RS485. Choose me plain, with LEDs, or with a 2.3 inch touch screen.

Interior rooms, hotels, schools; wall or standard 60 mm installation boxAsk about this

06 · Inputs, outputs and converters

Inputs, outputs and converters

Modules that bring dry contacts, relays, 0-20 mA, 4-20 mA and 0-60 V signals onto the 1-Wire UNI bus.

Need to connect something that is not an HW group sensor? These modules turn contacts, relays, current loops and DC voltages into 1-Wire UNI values.

Expander 4xDI 1W-UNI

Expander 4xDI 1W-UNI

36

Adds four dry contact digital inputs to the 1-Wire UNI bus of Ares and Poseidon units

  • Inputs4x Digital Input IN1 to IN4, NO/NC dry contact, 1 (On) = 0-500 Ω
  • Interface1-Wire UNI, 2x RJ11, max 60 m from the active port, 3m cable included
  • PowerFrom the RJ11 bus, max 2 Expander units per active port
  • Operating conditions-40 to +85 °C, 65 x 80 x 30 mm

I give you four dry contact inputs on the 1-Wire UNI bus, for pushbuttons, door contacts or a smoke detector relay. I occupy four sensor positions.

Ares, Poseidon 2250, Poseidon 4002 and all Poseidon2 productsAsk about this
Relay Output 1W-UNI

Relay Output 1W-UNI

37

Four NO/NC relay outputs for Ares 12 and Ares 14, switched by an alarm event or by SMS

  • Outputs4x switchable relay dry contact (NO/NC), OUT1 to OUT4
  • LoadMax 50 V / 1 A AC/DC, outputs galvanically insulated
  • Interface1-Wire UNI, 2x RJ11, max. 60 m, 3m cable included
  • PowerVia RJ11, max 2 modules per active port, external 5V adapter possible

I add four relay outputs to an Ares 12 or Ares 14. Switch alarms, air conditioning or heating from an alarm event or an SMS.

Ares 12 and Ares 14: optical and acoustical alarms, air condition, heating, power back-upsAsk about this
Sensor 0-20mA 1W-UNI

Sensor 0-20mA 1W-UNI

38

Isolated 0-20 mA current loop input for source-type industrial probes, on 1-Wire UNI

  • Input range0-20 mA (max. 30V), source type probe
  • Accuracy2% of the full 20mA range / 25°C, resolution 1 decimal place
  • Interface1Wire-UNI (RJ11), 2x RJ11 daisy-chain, max. 60m, bus powered
  • Isolation0-20mA input electrically isolated from the 1Wire-UNI bus

Feed me a 0-20 mA source signal, from a current transformer or a pressure transducer, and I show it on the 1-Wire UNI bus, isolated.

Current measurement with industrial probes, electronic scales, pressure transducersAsk about this
Sensor 4-20mA 1W-UNI

Sensor 4-20mA 1W-UNI

39

Isolated 4-20 mA current loop input that also powers the external sink-type probe

  • Input range4-20 mA (max. 30V external power), sink type probe
  • Accuracy2% of the full 4-20mA range / 25°C, resolution 1 decimal place
  • Interface1Wire-UNI (RJ11), 2x RJ11 daisy-chain, max. 60m
  • PowerRequires an external 12-30VDC power supply

I power your 4-20 mA sink probe from a 12-30 V DC supply and put its reading on the 1-Wire UNI bus. Tank levels and gas concentrations are typical jobs for me.

Fuel level in a tank, CO2 or other gas concentration, pressure transducers, pH sensorsAsk about this
Sensor 60V 1W-UNI v2

Sensor 60V 1W-UNI v2

40

Isolated DC voltage sensor, 0 to 60 V, for -48 V telco batteries and 0-10 V transducers

  • Input range0 to 60VDC (max. 70V); 0-1V, 0-10V, -48V DC
  • Accuracy2% of the full 60V range / 25°C, resolution 1 decimal place
  • Interface1Wire-UNI (RJ11), 2x RJ11 daisy-chain, max. 60m
  • Power1Wire-UNI bus or external 5VDC adapter, max 2 sensors per active port

I measure DC voltage up to 60 V, isolated, so I am at home on -48 V telco batteries, 12 V or 24 V car batteries and 0-10 V transducers.

Battery monitoring in telecommunication systems (telco -48V), 0-10V industrial probesAsk about this

Good to know · HW group

The portal, the alerts and the open API

Portal

SensDesk / HWg-cloud

HWg-cloud.com is the free portal from HW group for basic device management and email alerts; SensDesk.com is the paid service for professionals, from a single user with a few devices to projects with hundreds of devices, with a 30 days trial. SensDesk can also be licensed for your own servers (on premise), and third-party Portal providers run SensDesk Technology portals in local languages.

  • HWg-cloud.com: free of charge, up to 20 devices, email alerts to 2 targets, 10 days history, 1 dashboard
  • SensDesk.com: paid plans for 5 / 10 / 25 or more devices, 30 / 365 / 730 days history, 30 days trial
Alerts and reports

What the portal sends you

  • Alerts by email, SMS and voice call (SMS and calls via SMS-GW or Twilio service), logged, escalated or solved with comments
  • Automatic PDF reports; history downloadable as XLS, CSV, PDF, JPG, SVG
Integration

Open API and on premise

  • Open API: all sensor values of the account available via SNMP or XML
  • Remote output control: switch relay outputs manually, by sensor value or by conditions
  • On premise licences: SensDesk PRO (single tenant) and SensDesk DC (multi tenant)
  • Works with all HW group devices on LAN, WiFi, GSM, LTE or NB-IoT; HWg Monitor app for iOS and Android

Request a quote

Ask about HW group

Tell us about the site and which products you have in mind. Antech will get back to you with a quote.

  • PhoneAwaiting from Antech
  • EmailAwaiting from Antech

We only use your details to reply to this request.

Thanks. Your request is in, and Antech will get back to you.